Skip to main content
TIFFIN MOTORHOMES - SAP

Thetford C220 Toilet: Installation Guide

Introduction

 

This is the installation manual for the Thetford C223-CS toilet. The manual is meant for qualified installers who will install the toilet in a mobile leisure vehicle. Read the Information and Instructions carefully and follow them strictly to install the toilet safely and correctly.

Also read the warnings in the user manual before testing the toilet after installation.

Our policy is one of continuous development and improvement. Specifications and illustrations may change subsequent to publication.

Warning: If the appliance is not installed in accordance with national and European regulations, rules and standards this will void the warranty and may lead to criminal prosecution.

Regulations and Standards

Warning: Do not modify this appliance, unless the modification is authorized and carried out by the manufacturer or their agent.

Warning: Use only genuine and approved parts and materials.

Warning: Wear the correct Personal Protective Equipment during the installation. Also follow the applicable safety regulations.

 

Installation Audit Form

Thetford offers an additional service by auditing the installation of its product. This means that before a Thetford product is installed a Thetford local service representative will carry out a specific audit based on the Thetford installation instructions. The audit is meant as a reference for the specific model to ensure correct installation. In any case the Thetford local service representative can be contacted for any additional support related to the installation of the product.

Serviceability

The installer of Thetford products is responsible for proper installation to ensure the correct functionality and serviceability of the appliance. In terms of serviceability, this means that a dealer or an authorized Thetford service partner must be able to de-install and re-install the Thetford products within the time that is allowed according to the Thetford time-list, using standard tools and equipment.

This is to claim any warranty during the period of 3 years after purchase date. The serviceability of the product is also included in the audit. In case of any queries on this subject, please contact the Thetford local service representative before installing the product.

Designation codes, drawings and models

 

Each product has a specific identification code, the designation code. The designation code can be found on the data badge. See Servicing for the location of the data badge. The different positions of the code stand for different variations of the toilet. In these instructions, the designation will be used as reference.

Table 1: Designation example C22 3 S-N 062 x 30 C 01

C22 3 S -N 062 X 30 C 01
  Type of water supply Type of console     Slide out direction waste-holding tank   Type of level indication  

 

 

Designation Description 2D drawing 3D file
C224CW-x xxx x xx xxx C224-CW LE1242 LE1242
C223S-x xxx x xx xxx C223-S LE1243 LE1243
C223CS-x xxx x xx xxx C223-CS LE1244 LE1244
N/A Waste-holding tank C220 series LE1245 LE1245

 

Packaging

 

Type of packaging Pallet packaging 
Amount of toilets on a pallet 8
Maximum stack height 3 Pallets high
Pallet size 80x120cm

Position and Placement 

 

  • The main bathroom dimensions:

clipboard_e0d254087d31e56c69622179b4e00069b.png

  • The other dimensions:

clipboard_e227af8de23e5d277dc5d22f35654b68d.png

  • The bowl rotation:

clipboard_e8deb6e7e875eed323053c10fcbe97aaa.png

  • The floor-wall angle:

clipboard_eff1e330d1b7b8ecf072ea583133676e8.png

  • Create the wall cut-outs for the service door or flush door.

Note: See Designation codes, drawings and models for drawings of the cut-out dimensions.

  • Install the service door or flush door.
  • For further instructions, see the installation instructions of the door.

Note: The wall thickness needs to be between 23mm and 39mm for a service door or between 28mm and 40mm for a flush door. Contact Thetford if the vehicle wall thickness is outside this range.

  • Install the shower tray, if applicable.

clipboard_e44468de4d9910a37084c157f2c81d43c.png

  • Mount the wall bracket to the outside wall with two screws.
  • Connect toilet to the wall bracket.

clipboard_e2b683c213998b12767d451e7c3286a2d.png

  • Install the passive outside vent by guiding the tube to the outside, if applicable.

clipboard_ef0a121f35c8121374431f8c98e22335d.png

  • Mount the toilet to the floor with four screws.

Note: Required torque: 1.2 + or - 0.3 Nm for a plywood floor.

Note: Screws are supplied by Thetford. If these are not used, use stainless steel screws.

Note: Torque may differ if the floors is made from a different material.

clipboard_eb93047610dfbe6ca5f080c2c3a42fa8b.png

  • Connect the water hose. 
Diameter

Inside: 10mm

Outside: 16mm

Length and Position 

105mm from the last fixed point on the toilet

clipboard_ef1f14042a4b220c233c2c8b38e76587b.png

Required pressure remote pump at the toilet inlet

Min. 0.35bar at 4.2L/min

Max. 0.70bar at 7.1L/min

Maximum allowable pressure on hose

Europe: 4bar

AUS/CHINA/US: 8bar

 

Note: Make sure that after routing the water hose, the waste-holding tank can still be removed from the toilet.

Note: Meet the required pressure for the remote pump at the toilet inlet to ensure correct flush. If the pressure too high, install a flow reducer.

Note: If necessary, remove the cover on the splash guard to guide the water hose.

Connecting electricity

 

  • Connect the cable according to the following position.

clipboard_e9c49ebfc978d3c0ce7d6b355392f2f31.png

  • Use the following values to connect the power supply.
Remote Pump Grey and purple are used for remote pump relais. Minimum voltage and wattage as indicated on the pump must be respected.
Connection 4 pole tab housing
Position wiring in tab housing  clipboard_e3655895e1725a123e59ee48af4468019.png
4 pole connector on toilet TYCO/AMP 180901
4 pole connector counter part TYCO/AMP 180900
Thickness

Black/Red: 0.5mm²

Grey/Purple: 0.75mm²

 

Wiring Diagram

 

clipboard_ed3502949decdb3c0964ec2589dc83bf4.png

  • Over current protections: 3A PTC on PCBA
  • Control PCBA
  • Output relay on PCBA
  • 12V DC power supply
  • External flush pump (OEM)
  • Internal flush valve
  • 12V DC power supply

After Installation

 

  • Ensure that all packaging materials have been removed.
  • Check if the toilet flushes correctly.
  • Check if the level indication works.
  • Test all piping and connections and make sure they do not leak.

Technical Specifcations

  C223-CS toilet
Dimensions  H W D
mm 534 394 580
Empty weight  7.2kg
Capacity waste-holding tank 18L

 

Servicing

 

All servicing must be carried out by an approved competent person.

For service, please contact your authorized local Service Center giving details of the model and serial number on the data badge plus date of purchase.

The data badge can be found on the base of the toilet.

clipboard_ee7ef5a483cacd076ea25469ca9b31526.png